CO2 OEM Module-6004
6004
GE
Product Description:
CO2 OEM Module-6004 three different measurement range for choicing,meet different needs perfectly! Telaire 6004 CO2 OEM Module Options The 6004 CO2 OEM module is available in many different options. The optional items include measurement method, measurement range, and ABC LogicTM off/on. Here are the different available models: Part Number Range Accuracy* 6004F 0-2000 ppm ±40 ppm + 3% of reading 6004 0-2000 ppm ±40 ppm + 3% of reading 6004X 0-2000 ppm ±40 ppm + 3% of reading 6004-S5K 0-5,000 ppm ±150 ppm or 5% of reading, 6004X-S5K 0-5,000 ppm ±150 ppm + 5% of reading 6004-S50K 0-50,000 ppm ±200 ppm or 5% of reading 6004X-S50K 0-50,000 ppm ±200 ppm + 5% of reading * At 25C when measured against a factory certified reference ** Handling and OEM assembly may affect factory calibration. For best accuracy, modules should be zero calibrated once integrated into a product, prior to shipment. Specified accuracy is after re-zeroing process. *** When using ABC LogicTM which is a patented self-calibration technique that is designed to be used in applications where concentrations will drop to outside ambient conditions (approximately 400 ppm) at least 3 times in a 14 day period, typically during unoccupied periods. Application Small,compact CO2 module designed to integrate into existing controls and equipment.
three different measurement range for choicing,meet different needs perfectly!
Telaire 6004 CO2 OEM Module Options
The 6004 CO2 OEM module is available in many different options. The optional items include measurement method, measurement range, and ABC LogicTM off/on. Here are the different available models:
Part Number
Range
Accuracy*
6004F
0-2000 ppm
±40 ppm + 3% of reading
6004X
6004-S5K
0-5,000 ppm
±150 ppm or 5% of reading,
6004X-S5K
±150 ppm + 5% of reading
6004-S50K
0-50,000 ppm
±200 ppm or 5% of reading
6004X-S50K
±200 ppm + 5% of reading
* At 25C when measured against a factory certified reference
** Handling and OEM assembly may affect factory calibration. For best accuracy, modules should be zero calibrated once integrated into a product, prior to shipment. Specified accuracy is after re-zeroing process.
*** When using ABC LogicTM which is a patented self-calibration technique that is designed to be used in applications where concentrations will drop to outside ambient conditions (approximately 400 ppm) at least 3 times in a 14 day period, typically during unoccupied periods.