Gas sensors transmitters (Total 203 Products)
Brand: SST
Model Number: SprintIR6s
The SprintIR6S is our new super-fast CO2 sensor for high-speed application, and the response speed is unmatched by any other NDIR CO2 sensor.The SprintIR6S is a high speed CO2 sensor (20Hz) that can take up to 20 readings per second, with a...
Brand: FIGARO
Model Number: FCM2630
FCM2630 is an embedded type module using the semiconductor gas sensor TGS2630 which is optmized to detect the low-flammable refrigerant gas R-32.This module enables users to easily build a reliable gas leakage detection system by eliminatin...
Model Number: FAM-001-01
FAM-001-01 is combined with sensorTGS2600which detects indoor air quality, it is high sensitivity to low concentration pollutions, like cigarettes, cooking, TVOCS.Air Quality Detection ModuleFAM-001-01 Features :* Low power consumption* Lon...
Model Number: CGM6812
The CGM6812-B00 combustible gas sensor module isa new unit which utilizes TGS6812, Figaro's catalytic pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas...
Brand: Alphasense
Model Number: CO-A4
Specifications:(1) Range(ppm): 0~500(2) Sensitivity: 220~375 nA/ppm in 2ppm CO(3) Response time: t90 3years(6) Size(mm): Φ20.0×16.5(mm)(7) Linearity: linear at zero and 15ppm CO; < ± 1ppm CO error at full scale(8) Overgas limit: 2000...
Model Number: NO-A4
Specifications:(1) Range(ppm): 0~20(2) Sensitivity: 350~550 nA/ppm in 2ppm NO(3) Response time: t90 2years(6) Size(mm): Φ20.0×16.5(mm)(7) Linearity: linear at zero and 5ppm NO; < ± 1ppb error at full scale(8) Overgas limit: 50ppm(9) ...
Model Number: H2S-A4
Specifications:(1) Range(ppm): 0~50(2) Sensitivity: 1400~1850nA/ppm at 2ppm H2S(3) Response time: t90 2years(6) Size(mm): Φ20.0×16.5(mm)(7) Linearity: linear at zero and 10ppm H2S; < ± 0.5ppb error at full scale(8) Overgas limit: 100...
Model Number: NO2-A43F
PERFORMANCESensitivity nA/ppm at 2ppm NO2 -175 to -450Response time t90 (s) from zero to 2ppm NO2 < 60Zero current nA in zero air at 20℃ -50 to +70Noise* ±2 standard deviations (ppb equivalent) 15Range ppm NO 2 limit of performance ...
Model Number: SO2-A4
Specifications:(1) Range(ppm): 0~50(2) Sensitivity: 320~480nA/ppm at 2ppm SO2(3) Response time: t90 3years(6) Size(mm): Φ20.0×16.5(mm)(7) Linearity: linear at zero and 2ppm SO2; 0~-5ppb error at 20ppm SO2(8) Overgas limit: 100ppm(9) ...
Model Number: OX-B431
Specification O3 SensingPERFORMANCESensitivity nA/ppm at 1ppm O3 -225 to -650Response time t90 (s) from zero to 1ppm O3 < 45Zero current nA in zero air at 20°C -50 to 70Noise* ±2 standard deviations (ppb equivalent) 15Range ppm O3 limit of ...
Model Number: OX-A431
PERFORMANCESensitivity nA/ppm at 1ppm O3 -200 to -650Response time t90 (s) from zero to 1ppm O3 < 45Zero current nA in zero air at 20℃ -50 to 70Noise* ±2 standard deviations (ppb equivalent) ...
Model Number: OXY-COMM
一.Product descriptionThe OXY-COMM Zirconia Oxygen Analyser especially suitable for the industrial test control occasions, multi-point installation testing.The user can set the range of 0.1- 25% and 0.1 -100%.The entire measuring range is li...
Model Number: CDM7160
CDM7160 - Pre-Calibrated CO2 ModuleProduct Specifications/FeaturesCDM7160 - Pre-calibrated CO2 ModuleThe CDM7160 CO2 module uses a compact NDIRCO2 Sensor, featuring excellent performance characteristics, including high accuracy and low powe...
Model Number: O2S-FR-T4,Honeywell,KGZ-10SP
Flange Mounted Oxygen Sensor Family O2S-FR-T4Features: 1) Oxygen pressure range 2 mbar - 3bar2) Zirconium dioxide (ZrO2) sensing elements3) Non-consumption technology4) Integral heating element5) No need for temperature stabilisation6) No r...
Model Number: OPC-R1
Product Description:PM2.5 which can go directly to the lungs contains more toxic heavy metals and the hazardous organic pollutants, what’s more, it is more easily attached to bacteria and viruses in the environment, so the particles are gre...
Model Number: OPC-R2
PM2.5 which can go directly to the lungs contains more toxic heavy metals and the hazardous organic pollutants, what’s more, it is more easily attached to bacteria and viruses in the environment, so the particles are greater impacted on the...
Model Number: OPC-N3
OPC-N3 is the 3rd version of the particle counter based on OPC-N1 and OPC-N2. The appearance and dimension of OPC-N3 remains the same as that of OPC-N2, while its range has extended to 0.38~40um, meanwhile the number of channels has been ad...
Model Number: LOX-TRACE-1000-BLX
Optical Trace Oxygen Sensor LOX which can be exposed to any concentrations of O2 Model type: LOX-TRACE-1000-BLXDescription:Luminescence-based optical Lox sensor can be used to measure environment PPO2, it is non-depleting, consumes very low...
Model Number: TGS832-F01
Halogen gas sensor TGS832-F01Gas sensor TGS832-F01Measurement range: 1000-10000ppmSensitivity (resistance ratio) : 0.3-0.6Heater voltage: 5V±0.2V(AC/DC)Circuit voltage: 24V(AC/DC)Gas sensor TGS832-F01 main features:High sensitivity to R-134...
Model Number: TGS2603
Air quality sensor TGS2603Air quality sensor TGS2603 / air freshener sensor-- Indoor air quality testingAir quality sensor TGS2603/ air freshener with the main parameters of the sensorAir detection sensor measurement range: 1-30ppmCircuit v...